Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Phys Med Biol ; 69(8)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38471173

RESUMO

Objectives.Contouring similarity metrics are often used in studies of inter-observer variation and automatic segmentation but do not provide an assessment of clinical impact. This study focused on post-prostatectomy radiotherapy and aimed to (1) identify if there is a relationship between variations in commonly used contouring similarity metrics and resulting dosimetry and (2) identify the variation in clinical target volume (CTV) contouring that significantly impacts dosimetry.Approach.The study retrospectively analysed CT scans of 10 patients from the TROG 08.03 RAVES trial. The CTV, rectum, and bladder were contoured independently by three experienced observers. Using these contours reference simultaneous truth and performance level estimation (STAPLE) volumes were established. Additional CTVs were generated using an atlas algorithm based on a single benchmark case with 42 manual contours. Volumetric-modulated arc therapy (VMAT) treatment plans were generated for the observer, atlas, and reference volumes. The dosimetry was evaluated using radiobiological metrics. Correlations between contouring similarity and dosimetry metrics were calculated using Spearman coefficient (Γ). To access impact of variations in planning target volume (PTV) margin, the STAPLE PTV was uniformly contracted and expanded, with plans created for each PTV volume. STAPLE dose-volume histograms (DVHs) were exported for plans generated based on the contracted/expanded volumes, and dose-volume metrics assessed.Mainresults. The study found no strong correlations between the considered similarity metrics and modelled outcomes. Moderate correlations (0.5 <Γ< 0.7) were observed for Dice similarity coefficient, Jaccard, and mean distance to agreement metrics and rectum toxicities. The observations of this study indicate a tendency for variations in CTV contraction/expansion below 5 mm to result in minor dosimetric impacts.Significance. Contouring similarity metrics must be used with caution when interpreting them as indicators of treatment plan variation. For post-prostatectomy VMAT patients, this work showed variations in contours with an expansion/contraction of less than 5 mm did not lead to notable dosimetric differences, this should be explored in a larger dataset to assess generalisability.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Resultado do Tratamento
2.
Med Phys ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38465398

RESUMO

BACKGROUND: In the Unity MR linac (Elekta AB, Stockholm, Sweden), the radiation beam traverses the cryostat and the coil support structure. The resulting beam attenuation must be considered for output calibration and its variation with gantry angle must be characterized in the treatment planning system (TPS). PURPOSE: The aim of this work was to investigate the impact of a change of the cryostat transmission characterization (CTC) curve, due to the helium level modification, on clinical treatment plan dosimetry and to report on the experience with the CTC curve update. METHODS: Twenty stereotactic body radiotherapy (SBRT) treatment plans: 10 prostate and 10 oligo-metastatic cancer plans, prepared with a beam model incorporating the CTC curve acquired at installation time, were re-calculated using the model implementing CTC curve post helium top-up. To account for the CTC change as well as to align our system to the recent reference conditions recommendations, the new model was commissioned with the emphasis on the specifics associated with the treatment plan adaptation and the existence of the offline and online TPS components. RESULTS: Average CTV mean dose reduction by 0.45% in prostate cases and average GTV mean dose reduction by 0.22% in oligo-metastatic cases was observed. Updated model validation showcased good agreement between measurements and TPS calculations. CONCLUSIONS: The agreement between CTC measurements demonstrates its temporal constancy and robustness of the measurement method employed. A helium fill level change was shown to affect the CTC and led to a small but systematic dose calculation inaccuracy. Finally, model validation and end-to-end testing results presented, underscore the minimal impact of transitioning to the new beam model and new reference conditions.

3.
J Appl Clin Med Phys ; 25(4): e14253, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38394627

RESUMO

PURPOSE: The aim of this study was to assess the use of magnetic resonance guided adaptive radiotherapy (MRgART) in the post-prostatectomy setting; comparing dose accumulation for our initial seven patients treated with fully adaptive workflow on the Unity MR-Linac (MRL) and with non-adaptive plans generated offline. Additionally, we analyzed toxicity in patients receiving treatment. METHODS: Seven patients were treated with MRgART. The prescription was 70-72 Gy in 35-36 fractions. Patients were treated with an adapt to shape (ATS) technique. For each clinically delivered plan, a non-adaptive plan based upon the reference plan was generated and compared to the associated clinically delivered plan. A total of 468 plans were analyzed. Concordance Index of target and Organs at Risk (OARs) for each fraction with reference contours was analyzed. Acute toxicity was then assessed at six-months following completion of treatment with Common Terminology for Adverse Events (CTCAE) Toxicity Criteria. RESULTS: A total of 246 fractions were clinically delivered to seven patients; 234 fractions were delivered via MRgART and 12 fractions delivered via a traditional linear accelerator due to machine issues. Pre-treatment reference plans met CTV and OAR criteria. PTV coverage satisfaction was higher in the clinically delivered adaptive plans than non-adaptive comparison plans; 42.93% versus 7.27% respectively. Six-month CTCAE genitourinary and gastrointestinal toxicity was absent in most patients, and mild-to-moderate in a minority of patients (Grade 1 GU toxicity in one patient and Grade 2 GI toxicity in one patient). CONCLUSIONS: Daily MRgART treatment consistently met planning criteria. Target volume variability in prostate bed treatment can be mitigated by using MRgART and deliver satisfactory coverage of CTV whilst minimizing dose to adjacent OARs and reducing toxicity.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Masculino , Humanos , Dosagem Radioterapêutica , Fluxo de Trabalho , Planejamento da Radioterapia Assistida por Computador/métodos , Prostatectomia , Radioterapia de Intensidade Modulada/métodos , Espectroscopia de Ressonância Magnética
4.
Anal Bioanal Chem ; 416(11): 2835-2848, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38286852

RESUMO

This work presents the first systematic comparison of selenium (Se) speciation in plasma from cancer patients treated orally with three Se compounds (sodium selenite, SS; L-selenomethionine, SeMet; or Se-methylselenocysteine, MSC) at 400 µg/day for 28 days. The primary goal was to investigate how these chemical forms of Se affect the plasma Se distribution, aiming to identify the most effective Se compound for optimal selenoprotein expression. This was achieved using methodology based on HPLC-ICP-MS after sample preparation/fractionation approaches. Measurements of total Se in plasma samples collected before and after 4 weeks of treatment showed that median total Se levels increased significantly from 89.6 to 126.4 µg kg-1 Se (p < 0.001), particularly when SeMet was administered (190.4 µg kg-1 Se). Speciation studies showed that the most critical differences between treated and baseline samples were seen for selenoprotein P (SELENOP) and selenoalbumin after administration with MSC (p = 5.8 × 10-4) and SeMet (p = 6.8 × 10-5), respectively. Notably, selenosugar-1 was detected in all low-molecular-weight plasma fractions following treatment, particularly with MSC. Two different chromatographic approaches and spiking experiments demonstrated that about 45% of that increase in SELENOP levels (to ~ 8.8 mg L-1) with SeMet is likely due to the non-specific incorporation of SeMet into the SELENOP affinity fraction. To the authors' knowledge, this has not been reported to date. Therefore, SELENOP is probably part of both the regulated (55%) and non-regulated (45%) Se pools after SeMet administration, whereas SS and MSC mainly contribute to the regulated one.


Assuntos
Neoplasias , Compostos de Selênio , Selênio , Humanos , Selenometionina , Neoplasias/tratamento farmacológico , Biomarcadores
5.
Asia Pac J Clin Oncol ; 20(1): 71-80, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37340953

RESUMO

Rectal cancer is a common malignancy. The management of rectal cancer has recently evolved and has undergone a paradigm shift with the advent of treatment approaches such as total neoadjuvant therapy and the watch-and-wait approach. However, despite the recently available evidence, there is no consensus on the optimal management approach in the setting of locally advanced rectal cancer. To address some of the controversies, a joint multidisciplinary panel discussion was conducted at the Australasian Gastro-Intestinal Trials Group (AGITG) Annual Scientific Meeting in November 2022. Members from different subspecialties formed two panels and discussed three clinical cases in a debate format. Each case represented some of the complex issues faced by clinicians in this setting. The discussion is now presented in this manuscript, which depicts the different available management approaches and reiterates the importance of a multidisciplinary approach.


Assuntos
Terapia Neoadjuvante , Neoplasias Retais , Humanos , Neoplasias Retais/terapia , Neoplasias Retais/patologia , Equipe de Assistência ao Paciente , Recidiva Local de Neoplasia/patologia , Resultado do Tratamento , Quimiorradioterapia
6.
Nat Commun ; 14(1): 5840, 2023 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-37730757

RESUMO

Diabetes mellitus increases risk for tuberculosis disease and adverse outcomes. Most people with both conditions have type 2 diabetes, but it is unknown if type 1 and type 2 diabetes have identical effects on tuberculosis susceptibility. Here we show that male mice receiving a high-fat diet and streptozotocin to model type 2 diabetes, have higher mortality, more lung pathology, and higher bacterial burden following Mycobacterium tuberculosis infection compared to mice treated with streptozotocin or high-fat diet alone. Type 2 diabetes model mice have elevated plasma glycerol, which is a preferred carbon source for M. tuberculosis. Infection studies with glycerol kinase mutant M. tuberculosis reveal that glycerol utilization contributes to the susceptibility of the type 2 diabetes mice. Hyperglycemia impairs protective immunity against M. tuberculosis in both forms of diabetes, but our data show that elevated glycerol contributes to an additional adverse effect uniquely relevant to type 2 diabetes.


Assuntos
Diabetes Mellitus Tipo 2 , Mycobacterium tuberculosis , Tuberculose , Humanos , Masculino , Animais , Camundongos , Diabetes Mellitus Tipo 2/complicações , Glicerol , Estreptozocina
7.
J Med Radiat Sci ; 70(4): 491-497, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37540059

RESUMO

The magnetic resonance linear accelerator (MR-Linac) offers a new treatment paradigm, providing improved visualisation of targets and organs at risk while allowing for daily adaptation of treatment plans in real time. Online MR-guided adaptive treatment has reduced treatment uncertainties; however, the additional treatment time and resource requirements may be a concern. We present our experience of integrating an MR-Linac into a busy department and provide recommendations for improved clinical and resource efficiency. Furthermore, we discuss potential future technological innovations that can further optimise clinical productivity in a busy department.


Assuntos
Imageamento por Ressonância Magnética , Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador
8.
Phys Med Biol ; 68(19)2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37652043

RESUMO

Objective. This study aimed to investigate the dosimetric impact of using population-based relative electron density (RED) overrides in lieu of simulation computerized tomography (CT) in a magnetic resonance linear accelerator (MRL) workflow for male pelvis patients. Additionally, the feasibility of using prostate specific membrane antigen positron emission tomography/CT (PSMA-PET/CT) scans to assess patients' eligibility for this proposed workflow was examined.Approach. In this study, 74 male pelvis patients treated on an Elekta Unity 1.5 T MRL were retrospectively selected. The patients' individual RED values for 8 organs of interest were extracted from their simulation-CT images to establish population-based RED values. These values were used to generate individual (IndD) and population-based (PopD) RED dose plans, representing current and proposed MRL workflows, respectively. Lastly, this study compared RED values obtained from CT and PET-CT scanners in a phantom and a subset of patients.Results. Population-based RED values were mostly within two standard deviations of ICRU Report 46 values. PopD plans were comparable to IndD plans, with the average %difference magnitudes of 0.5%, 0.6%, and 0.6% for mean dose (all organs), D0.1cm3(non-target organs) and D95%/D98% (target organs), respectively. Both phantom and patient PET-CT derived RED values had high agreement with corresponding CT-derived values, with correlation coefficients ≥ 0.9.Significance. Population-based RED values were considered suitable in a simulation-free MRL treatment workflow. Utilizing these RED values resulted in similar dosimetric uncertainties as per the current workflow. Initial findings also suggested that PET-CT scans may be used to assess prospective patients' eligibility for the proposed workflow. Future investigations will evaluate the clinical feasibility of implementing this workflow for prospective patients in the clinical setting. This is aimed to reduce patient burden during radiotherapy and increase department efficiencies.


Assuntos
Elétrons , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
9.
Eur Radiol ; 33(12): 8788-8799, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37405500

RESUMO

OBJECTIVES: To test if tumour changes measured using combination of diffusion-weighted imaging (DWI) MRI and FDG-PET/CT performed serially during radiotherapy (RT) in mucosal head and neck carcinoma can predict treatment response. METHODS: Fifty-five patients from two prospective imaging biomarker studies were analysed. FDG-PET/CT was performed at baseline, during RT (week 3), and post RT (3 months). DWI was performed at baseline, during RT (weeks 2, 3, 5, 6), and post RT (1 and 3 months). The ADCmean from DWI and FDG-PET parameters SUVmax, SUVmean, metabolic tumour volume (MTV), and total lesion glycolysis (TLG) were measured. Absolute and relative change (%∆) in DWI and PET parameters were correlated to 1-year local recurrence. Patients were categorised into favourable, mixed, and unfavourable imaging response using optimal cut-off (OC) values of DWI and FDG-PET parameters and correlated to local control. RESULTS: The 1-year local, regional, and distant recurrence rates were 18.2% (10/55), 7.3% (4/55), and 12.7% (7/55), respectively. ∆Week 3 ADCmean (AUC 0.825, p = 0.003; OC ∆ > 24.4%) and ∆MTV (AUC 0.833, p = 0.001; OC ∆ > 50.4%) were the best predictors of local recurrence. Week 3 was the optimal time point for assessing DWI imaging response. Using a combination of ∆ADCmean and ∆MTV improved the strength of correlation to local recurrence (p ≤ 0.001). In patients who underwent both week 3 MRI and FDG-PET/CT, significant differences in local recurrence rates were seen between patients with favourable (0%), mixed (17%), and unfavourable (78%) combined imaging response. CONCLUSIONS: Changes in mid-treatment DWI and FDG-PET/CT imaging can predict treatment response and could be utilised in the design of future adaptive clinical trials. CLINICAL RELEVANCE STATEMENT: Our study shows the complementary information provided by two functional imaging modalities for mid-treatment response prediction in patients with head and neck cancer. KEY POINTS: •FDG-PET/CT and DWI MRI changes in tumour during radiotherapy in head and neck cancer can predict treatment response. •Combination of FDG-PET/CT and DWI parameters improved correlation to clinical outcome. •Week 3 was the optimal time point for DWI MRI imaging response assessment.


Assuntos
Neoplasias de Cabeça e Pescoço , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Compostos Radiofarmacêuticos , Estudos Prospectivos , Tomografia por Emissão de Pósitrons , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia
10.
Radiother Oncol ; 186: 109794, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37414257

RESUMO

BACKGROUND AND PURPOSE: Previous studies on automatic delineation quality assurance (QA) have mostly focused on CT-based planning. As MRI-guided radiotherapy is increasingly utilized in prostate cancer treatment, there is a need for more research on MRI-specific automatic QA. This work proposes a clinical target volume (CTV) delineation QA framework based on deep learning (DL) for MRI-guided prostate radiotherapy. MATERIALS AND METHODS: The proposed workflow utilized a 3D dropblock ResUnet++ (DB-ResUnet++) to generate multiple segmentation predictions via Monte Carlo dropout which were used to compute an average delineation and area of uncertainty. A logistic regression (LR) classifier was employed to classify the manual delineation as pass or discrepancy based on the spatial association between the manual delineation and the network's outputs. This approach was evaluated on a multicentre MRI-only prostate radiotherapy dataset and compared with our previously published QA framework based on AN-AG Unet. RESULTS: The proposed framework achieved an area under the receiver operating curve (AUROC) of 0.92, a true positive rate (TPR) of 0.92 and a false positive rate of 0.09 with an average processing time per delineation of 1.3 min. Compared with our previous work using AN-AG Unet, this method generated fewer false positive detections at the same TPR with a much faster processing speed. CONCLUSION: To the best of our knowledge, this is the first study to propose an automatic delineation QA tool using DL with uncertainty estimation for MRI-guided prostate radiotherapy, which can potentially be used for reviewing prostate CTV delineation in multicentre clinical trials.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Radioterapia Guiada por Imagem , Humanos , Masculino , Garantia da Qualidade dos Cuidados de Saúde , Imageamento por Ressonância Magnética , Incerteza , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia
11.
Radiother Oncol ; 186: 109745, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37330056

RESUMO

BACKGROUND: The aim of this study was to measure functional changes in parotid glands using mid-treatment FDG-PET/CT and correlate early imaging changes to subsequent xerostomia in mucosal head and neck squamous cell carcinoma patients undergoing radiotherapy. MATERIALS AND METHODS: 56 patients from two prospective imaging biomarker studies underwent FDG-PET/CT at baseline and during radiotherapy (week 3). Both parotid glands were volumetrically delineated at each time point. PET parameter SUVmedian were calculated for ipsilateral and contralateral parotid glands. Absolute and relative change (Δ) in SUVmedian were correlated to moderate-severe xerostomia (CTCAE grade ≥ 2) at 6 months. Four predictive models were subsequently created using multivariate logistic regression using clinical and radiotherapy planning parameters. Model performance was calculated using ROC analysis and compared using Akaike information criterion (AIC) RESULTS: 29 patients (51.8%) developed grade ≥ 2 xerostomia. Compared to baseline, there was an increase in SUVmedian at week 3 in ipsilateral (8.4%) and contralateral (5.5%) parotid glands. Increase in ipsilateral parotid Δ SUVmedian (p = 0.04) and contralateral mean parotid dose (p = 0.04) were correlated to xerostomia. The reference 'clinical' model correlated to xerostomia (AUC 0.667, AIC 70.9). Addition of ipsilateral parotid Δ SUVmedian to the clinical model resulted in the highest correlation to xerostomia (AUC 0.777, AIC 65.4). CONCLUSION: Our study shows functional changes occurring in the parotid gland early during radiotherapy. We demonstrate that integration of baseline and mid-treatment FDG-PET/CT changes in the parotid gland with clinical factors has the potential to improve xerostomia risk prediction which could be utilised for personalised head and neck radiotherapy.


Assuntos
Neoplasias de Cabeça e Pescoço , Lesões por Radiação , Xerostomia , Humanos , Fluordesoxiglucose F18 , Dosagem Radioterapêutica , Glândula Parótida/diagnóstico por imagem , Glândula Parótida/patologia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/patologia , Estudos Prospectivos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Xerostomia/diagnóstico por imagem , Xerostomia/etiologia , Xerostomia/patologia , Lesões por Radiação/patologia , Tomografia por Emissão de Pósitrons
12.
Quant Imaging Med Surg ; 13(5): 2822-2836, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37179931

RESUMO

Background: The aim of this study was to evaluate the impact of tumour region of interest (ROI) delineation method on mid-treatment 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) response prediction in mucosal head and neck squamous cell carcinoma during radiotherapy. Methods: A total of 52 patients undergoing definitive radiotherapy with or without systemic therapy from two prospective imaging biomarker studies were analysed. FDG-PET was performed at baseline and during radiotherapy (week 3). Primary tumour was delineated using a fixed SUV 2.5 threshold (MTV2.5), relative threshold (MTV40%) and a gradient based segmentation method (PET Edge). PET parameters SUVmax, SUVmean, metabolic tumour volume (MTV) and total lesion glycolysis (TLG) were calculated using different ROI methods. Absolute and relative change (∆) in PET parameters were correlated to 2-year locoregional recurrence. Strength of correlation was tested using receiver operator characteristic analysis using area under the curve (AUC). Response was categorized using optimal cut-off (OC) values. Correlation and agreement between different ROI methods was determined using Bland-Altman analysis. Results: A significant difference in SUVmean, MTV and TLG values were noted between ROI delineation methods. When measuring relative change at week 3, a greater agreement was seen between PET Edge and MTV2.5 methods with average difference in ∆SUVmax, ∆SUVmean, ∆MTV and ∆TLG of 0.0%, 3.6%, 10.3% and 13.6% respectively. A total of 12 patients (22.2%) experienced locoregional recurrence. ∆MTV using PET Edge was the best predictor of locoregional recurrence (AUC =0.761, 95% CI: 0.573-0.948, P=0.001; OC ∆>50%). The corresponding 2-year locoregional recurrence rate was 7% vs. 35%, P=0.001. Conclusions: Our findings suggest that it is preferable to use gradient based method to assess volumetric tumour response during radiotherapy and offers advantage in predicting treatment outcomes compared with threshold-based methods. This finding requires further validation and can assist in future response-adaptive clinical trials.

13.
J Med Radiat Sci ; 70(2): 199-205, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36890690

RESUMO

We present the first case in the literature of a 78-year-old woman with recurrent cardiac sarcoma adjacent to a bioprosthetic mitral valve treated with magnetic resonance linear accelerator (MR-Linac) guided adaptive stereotactic ablative body radiotherapy (SABR). The patient was treated using a 1.5 T Unity MR-Linac system (Elekta AB, Stockholm, Sweden). The mean gross tumour volume (GTV) size was 17.9 cm3 (range 16.6-18.9 cm3 ) based on daily contours and the mean dose received by the GTV was 41.4 Gy (range 40.9-41.6 Gy) in five fractions. All fractions were completed as planned and the patient tolerated the treatment well with no acute toxicity reported. Follow-up appointments at 2 and 5 months after the last treatment showed stable disease and good symptomatic relief. Results of transthoracic echocardiogram after radiotherapy showed that the mitral valve prosthesis was normally seated with regular functionality. This study provides evidence that MR-Linac guided adaptive SABR is a safe and viable option for the treatment of recurrent cardiac sarcoma with mitral valve bioprosthesis.


Assuntos
Bioprótese , Radiocirurgia , Sarcoma , Feminino , Humanos , Idoso , Valva Mitral/cirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Sarcoma/diagnóstico por imagem , Sarcoma/radioterapia , Sarcoma/cirurgia
14.
Radiother Oncol ; 182: 109527, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36773825

RESUMO

Dose mapping/accumulation (DMA) is a topic in radiotherapy (RT) for years, but has not yet found its widespread way into clinical RT routine. During the ESTRO Physics workshop 2021 on "commissioning and quality assurance of deformable image registration (DIR) for current and future RT applications", we built a working group on DMA from which we present the results of our discussions in this article. Our aim in this manuscript is to shed light on the current situation of DMA in RT and to highlight the issues that hinder consciously integrating it into clinical RT routine. As a first outcome of our discussions, we present a scheme where representative RT use cases are positioned, considering expected anatomical variations and the impact of dose mapping uncertainties on patient safety, which we have named the DMA landscape (DMAL). This tool is useful for future reference when DMA applications get closer to clinical day-to-day use. Secondly, we discussed current challenges, lightly touching on first-order effects (related to the impact of DIR uncertainties in dose mapping), and focusing in detail on second-order effects often dismissed in the current literature (as resampling and interpolation, quality assurance considerations, and radiobiological issues). Finally, we developed recommendations, and guidelines for vendors and users. Our main point include: Strive for context-driven DIR (by considering their impact on clinical decisions/judgements) rather than perfect DIR; be conscious of the limitations of the implemented DIR algorithm; and consider when dose mapping (with properly quantified uncertainties) is a better alternative than no mapping.


Assuntos
Radioterapia (Especialidade) , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
15.
Phys Eng Sci Med ; 46(1): 19-43, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36847966

RESUMO

Magnetic Resonance Imaging linear-accelerator (MRI-linac) equipment has recently been introduced to multiple centres in Australia and New Zealand. MRI equipment creates hazards for staff, patients and others in the MR environment; these hazards must be well understood, and risks managed by a system of environmental controls, written procedures and a trained workforce. While MRI-linac hazards are similar to the diagnostic paradigm, the equipment, workforce and environment are sufficiently different that additional safety guidance is warranted. In 2019 the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) formed the Magnetic Resonance Imaging Linear-Accelerator Working Group (MRILWG) to support the safe clinical introduction and optimal use of MR-guided radiation therapy treatment units. This Position Paper is intended to provide safety guidance and education for Medical Physicists and others planning for and working with MRI-linac technology. This document summarises MRI-linac hazards and describes particular effects which arise from the combination of strong magnetic fields with an external radiation treatment beam. This document also provides guidance on safety governance and training, and recommends a system of hazard management tailored to the MRI-linac environment, ancillary equipment, and workforce.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Aceleradores de Partículas , Recursos Humanos , Austrália
16.
J Med Imaging Radiat Oncol ; 67(1): 89-97, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36300564

RESUMO

INTRODUCTION: Tumour recurrences after treatment of head and neck squamous cell carcinoma (HNSCC) are more likely to originate from regions of high-baseline FDG-PET uptake. Mid-treatment functional imaging can potentially predict for higher risk of tumour recurrence. The aim of this study is to correlate the location of locoregional tumour recurrence with baseline FDG-PET metabolic volumes and mid-treatment FDG-PET metabolic volumes in patients with HNSCC following definitive radiotherapy. METHODS: A total of 23 patients with 26 local and/or regional recurrences underwent baseline (W0-PET) and mid-treatment (W3-PET) 18F-FDG PET scans as part of their radiotherapy. FDG-PET-based metabolic volumes (MTV20%, MTV40%, MTV60%, MTV80%, SUV2.5, SUVpeak and PET_EDGE) were delineated onto the FDG-PET scans. The recurrence nidus was identified on FDG-PET at the time of recurrence (REC-PET). DIR-based fusion was performed for REC-PET to W0-PET, and REC-PET to W3-PET. The location of the recurrence nidus was correlated with the FDG-PET volumes. Further analysis included a comparison of the recurrence density to FDG-PET metabolic volumes. RESULTS: Most recurrences occurred within the MTV20%, MTV40% and SUV 2.5 volumes. Sixty-nine per cent of recurrences (18 of 26) occurred within both the W0 MTV40% and W3 MTV40% volumes. A higher recurrence density was seen for iso-SUV contours closer to the maximum SUV for both W0 and W3. For a number of the FDG-PET volumes, including MTV20%, MTV40% and SUV2.5, the recurrence density was improved for W3 compared to W0, however, this improvement was small in magnitude. The average volume of MTV40% contours was considerably smaller than MTV20% and SUV2.5 contours. CONCLUSION: The metabolic parameters of SUV2.5, MTV20% and MTV40% delineated on the baseline and mid-treatment FDG-PET scans encompassed the majority of recurrences. The MTV40% is significantly smaller, hence, we prefer this volume for future dose escalation studies.


Assuntos
Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço , Humanos , Recidiva Local de Neoplasia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Recidiva , Carcinoma de Células Escamosas de Cabeça e Pescoço
17.
J Med Radiat Sci ; 70 Suppl 2: 99-106, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36502538

RESUMO

The introduction of magnetic resonance (MR) linear accelerators (MR-Linacs) into radiotherapy departments has increased in recent years owing to its unique advantages including the ability to deliver online adaptive radiotherapy. However, most radiation oncology professionals are not accustomed to working with MR technology. The integration of an MR-Linac into routine practice requires many considerations including MR safety, MR image acquisition and optimisation, image interpretation and adaptive radiotherapy strategies. This article provides an overview of training and credentialing requirements for radiation oncology professionals to develop competency and efficiency in delivering treatment safely on an MR-Linac.


Assuntos
Radio-Oncologistas , Radioterapia Guiada por Imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Aceleradores de Partículas , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Espectroscopia de Ressonância Magnética , Credenciamento
18.
J Med Radiat Sci ; 70 Suppl 2: 94-98, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36572532

RESUMO

The introduction of magnetic resonance (MR) linear accelerators (MR-Linac) marks the beginning of a new era in radiotherapy. MR-Linac systems are currently being operated by teams of radiation therapists (RTs), radiation oncology medical physicists (ROMPs) and radiation oncologists (ROs) due to the diverse and complex tasks required to deliver treatment. This is resource-intensive and logistically challenging. RT-led service delivery at the treatment console is paramount to simplify the process and make the best use of this technology for suitable patients with commonly treated anatomical sites. This article will discuss the experiences of our department in developing and implementing an RT-led workflow on the 1.5 T MR-Linac.


Assuntos
Radioterapia (Especialidade) , Radioterapia Guiada por Imagem , Humanos , Imageamento por Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador , Espectroscopia de Ressonância Magnética
19.
JCO Clin Cancer Inform ; 6: e2200064, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36265112

RESUMO

PURPOSE: Predicting short-term mortality in patients with advanced cancer remains challenging. Whether digitalized clinical text can be used to build models to enhance survival prediction in this population is unclear. MATERIALS AND METHODS: We conducted a single-centered retrospective cohort study in patients with advanced solid tumors. Clinical correspondence authored by oncologists at the first patient encounter was extracted from the electronic medical records. Machine learning (ML) models were trained using narratives from the derivation cohort, before being tested on a temporal validation cohort at the same site. Performance was benchmarked against Eastern Cooperative Oncology Group performance status (PS), comparing ML models alone (comparison 1) or in combination with PS (comparison 2), assessed by areas under receiver operating characteristic curves (AUCs) for predicting vital status at 11 time points from 2 to 52 weeks. RESULTS: ML models were built on the derivation cohort (4,791 patients from 2001 to April 2017) and tested on the validation cohort of 726 patients (May 2017-June 2019). In 441 patients (61%) where clinical narratives were available and PS was documented, ML models outperformed the predictivity of PS (mean AUC improvement, 0.039, P < .001, comparison 1). Inclusion of both clinical text and PS in ML models resulted in further improvement in prediction accuracy over PS with a mean AUC improvement of 0.050 (P < .001, comparison 2); the AUC was > 0.80 at all assessed time points for models incorporating clinical text. Exploratory analysis of oncologist's narratives revealed recurring descriptors correlating with survival, including referral patterns, mobility, physical functions, and concomitant medications. CONCLUSION: Applying ML to oncologists' narratives with or without including patient's PS significantly improved survival prediction to 12 months, suggesting the utility of clinical text in building prognostic support tools.


Assuntos
Aprendizado de Máquina , Neoplasias , Humanos , Estudos Retrospectivos , Neoplasias/diagnóstico , Neoplasias/terapia , Neoplasias/epidemiologia , Registros Eletrônicos de Saúde , Prognóstico
20.
Clin Transl Radiat Oncol ; 36: 121-126, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36017132

RESUMO

Background: During the last decade, radiotherapy using MR Linac has gone from research to clinical implementation for different cancer locations. For head and neck cancer (HNC), target delineation based only on MR images is not yet standard, and the utilisation of MRI instead of PET/CT in radiotherapy planning is not well established. We aimed to analyse the inter-observer variation (IOV) in delineating GTV (gross tumour volume) on MR images only for patients with HNC. Material/methods: 32 HNC patients from two independent departments were included. Four clinical oncologists from Denmark and four radiation oncologists from Australia had independently contoured primary tumour GTVs (GTV-T) and nodal GTVs (GTV-N) on T2-weighted MR images obtained at the time of treatment planning. Observers were provided with sets of images, delineation guidelines and patient synopsis. Simultaneous truth and performance level estimation (STAPLE) reference volumes were generated for each structure using all observer contours. The IOV was assessed using the DICE Similarity Coefficient (DSC) and mean absolute surface distance (MASD). Results: 32 GTV-Ts and 68 GTV-Ns were contoured per observer. The median MASD for GTV-Ts and GTV-Ns across all patients was 0.17 cm (range 0.08-0.39 cm) and 0.07 cm (range 0.04-0.33 cm), respectively. Median DSC relative to a STAPLE volume for GTV-Ts and GTV-Ns across all patients were 0.73 and 0.76, respectively. A significant correlation was seen between median DSCs and median volumes of GTV-Ts (Spearman correlation coefficient 0.76, p < 0.001) and of GTV-Ns (Spearman correlation coefficient 0.55, p < 0.001). Conclusion: Contouring GTVs in patients with HNC on MRI showed that the median IOV for GTV-T and GTV-N was below 2 mm, based on observes from two separate radiation departments. However, there are still specific regions in tumours that are difficult to resolve as either malignant tissue or oedema that potentially could be improved by further training in MR-only delineation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA